- Accessory directory
- Ladegeräte für Hörgeräte
- Starkey StarLink Charger 2.0 (mRIC R)
Starkey StarLink Charger 2.0 (mRIC R)
Laden Sie kompatible Starkey Receiver-in-Canal Hörgeräte und bewahren Sie sie in einem Scharnieretui auf.
Was StarLink Charger 2.0 (mRIC R) kann
Verwenden Sie dieses Etui, um zwei kompatible Starkey Receiver-in-Canal-Hörgeräte zu laden. Während des Ladens der Hörgeräte ist eine externe Stromquelle erforderlich. Wenn ein Hörgerät schwach geladen ist, bietet Turbo Charge laut Starkey nach zehn Minuten etwa drei Stunden Nutzung.
Which hearing aids work with Starkey StarLink Charger 2.0 (mRIC R)?
Laden
- Starkey Genesis AI mRIC R
Genesis AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111. Use the case with the matching mRIC R charging wells.
- Starkey Edge AI mRIC R
Edge AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111. Use the case with the matching mRIC R charging wells.
- Starkey Omega AI mRIC R
Omega AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111. Use the case with the matching mRIC R charging wells.
Wählen Sie das genaue Modell auf Ihren Hörgeräten oder Unterlagen. Ein Treffer für eine Produktfamilie belegt nicht die Unterstützung jedes Modells dieser Familie.
Dokumentierte Geräte und Konfigurationen anzeigen
- Starkey Genesis AI mRIC R · Genaues Modell
Case marked mRIC R · Laden
Genesis AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
Zusätzliche Einrichtung erforderlichQuelle · 2026-11-18Genesis AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
- Use the case with the matching mRIC R charging wells.
- Starkey Edge AI mRIC R · Genaues Modell
Case marked mRIC R · Laden
Edge AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
Zusätzliche Einrichtung erforderlichQuelle · 2026-11-18Edge AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
- Use the case with the matching mRIC R charging wells.
- Starkey Omega AI mRIC R · Genaues Modell
Case marked mRIC R · Laden
Omega AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
Zusätzliche Einrichtung erforderlichQuelle · 2026-11-18Omega AI mRIC R requires the mRIC R well shape. U.S. commercial order code P00009111.
- Use the case with the matching mRIC R charging wells.
Dokumentierte Funktionen
Power and charging
- Automatic hearing-aid power
- When the charger has power, compatible aids turn off and start charging when seated. They turn on when removed.Dokumentation · 2026-11-18
- Hearing-aid and receiver fit
- This version fits documented mRIC R styles from Genesis AI, Edge AI, and the original Omega AI. Use the separately marked RIC RT case if that is your style. Compare the part number P00009111 with your hearing aids before ordering.Dokumentation · 2026-11-18
- Charging indicators
- The side lights blink during charging and stay lit when full. Rapid blinking calls for checking placement, contacts, and the power supply.Dokumentation · 2026-11-18
- Charging method
- Contact charging in separate left and right wells for the matching rechargeable RIC shell.Dokumentation · 2026-11-18
- Charging slots
- 2 aids
Separate left and right wells are shown in the manufacturer’s diagrams.
Dokumentation · 2026-11-18 - Charging temperature limits
- 50–104 °F (10–40 °C), 10–95% relative humidity, and 70–106 kPa.Dokumentation · 2026-11-18
- Full hearing-aid charge time
- 3,5 Stunden
Starkey’s 2.0 guide gives the figure for compatible rechargeable hearing aids. It does not specify individual model or remaining charge.
Dokumentation · 2026-11-18 - Lid behavior while charging
- Charging works with the lid open or closed. Let the domes or earmolds rest in the center space and close the lid for storage.Dokumentation · 2026-11-18
- Laden nur mit externer Stromversorgung
Requires an external power source while charging the hearing aids.
Dokumentation · 2026-11-18- Power connector
- USB-C port on the case.
Use a power cable and adapter approved or listed by a recognized testing laboratory.
Dokumentation · 2026-11-18 - Quick charge duration
- 10 Minuten
Turbo Charge starts automatically when the hearing-aid battery is low.
Dokumentation · 2026-11-18 - Runtime after quick charge
- About 3 hours after a 10-minute Turbo ChargeDokumentation · 2026-11-18
- USB-C power input
- UnterstütztDokumentation · 2026-11-18
Care and fit
- Cleaning materials
- Use the supplied cleaning tool on the contacts. Keep water, cleaning liquids, and solvents away from the contacts.Dokumentation · 2026-11-18
Design and everyday use
- Dimensions
- 92 × 63 × 56 mm in Starkey’s published order.
The manufacturer does not label the axes. A reseller reports approximate dimensions of 90 × 50 × 50 mm for its unit.
Dokumentation · 2026-11-18 - Included items
- Charging case, USB charging cable · Unter bestimmten Bedingungen
Item list for the observed retailer offer only. The maker’s user guide mentions a cleaning tool. Confirm the U.S. box with the seller.
Dokumentation · 2026-11-18 - Routine maintenance
- Use the supplied cleaning tool to clear debris from the charging contacts. Keep the lid closed for storage in a cool, dry place. Unplug the charger if storing it for more than a week.Dokumentation · 2026-11-18
- Operating conditions
- Charge within 50–104 °F (10–40 °C) and 10–95% relative humidity. Keep the contacts dry.Dokumentation · 2026-11-18
- Regional variants
- U.S. commercial part P00009111. The May–October 2026 U.S. Government Services form uses P00008298. Other contract periods may use different codes.
Separate ordering channels. Confirm the actual part number and fit with the supplier.
Dokumentation · 2026-11-18 - Required extras
- External power source while charging aids, Approved cable and power adapter, Rechargeable hearing aids with the matching shell shapeDokumentation · 2026-11-18
- Repair and service options
- Contact your hearing care provider if reseating the aids or cleaning the contacts does not help. The manufacturer instructs owners to send a defective charger for repair and keep the case assembled.Dokumentation · 2026-11-18
- Status indicators
- Left and right hearing-aid lights
Both sides blink during charging and stay on when full. See case battery lights for the Premium model.
Dokumentation · 2026-11-18 - Storage conditions
- Store and transport at 14–113 °F (−10–45 °C), 10–95% relative humidity, and 70–106 kPa.Dokumentation · 2026-11-18
- Weight
- 117 g
Starkey lists 117 g for this RIC case type, without a different figure for each well shape.
Dokumentation · 2026-11-18
How to set up Starkey StarLink Charger 2.0 (mRIC R)
Schließen Sie das Ladegerät mit einem geeigneten USB-C-Stromkabel und Adapter an eine Steckdose an. Setzen Sie die linken und rechten Hörgeräte in die passenden Steckplätze. Legen Sie die Schirmchen oder Ohrpassstücke in die Mitte. Die seitlichen Leuchten blinken während des Ladevorgangs und leuchten dauerhaft, wenn die Hörgeräte vollständig geladen sind. Durch das Herausnehmen der Hörgeräte werden sie eingeschaltet.
Vor dem Kauf prüfen
This version fits documented mRIC R styles from Genesis AI, Edge AI, and the original Omega AI. Use the separately marked RIC RT case if that is your style. The RIC and custom in-ear chargers have different wells. Match the exact order code and style before buying. Requires an external power source while charging the hearing aids.
Match the charging wells to your hearing aids
This version fits documented mRIC R styles from Genesis AI, Edge AI, and the original Omega AI. Use the separately marked RIC RT case if that is your style. Compare the part number P00009111 with your hearing aids before ordering.
QuelleCheck the charging lights
Schließen Sie das Ladegerät mit einem geeigneten USB-C-Stromkabel und Adapter an eine Steckdose an. Setzen Sie die linken und rechten Hörgeräte in die passenden Steckplätze. Legen Sie die Schirmchen oder Ohrpassstücke in die Mitte. Die seitlichen Leuchten blinken während des Ladevorgangs und leuchten dauerhaft, wenn die Hörgeräte vollständig geladen sind. Durch das Herausnehmen der Hörgeräte werden sie eingeschaltet.
QuelleNeeds a power source to charge mRIC R aids
For compatible Starkey mRIC R aids, the difference between this case and the StarLink Premium Charger 2.0 (mRIC R) shows up when you travel. The standard case needs external power for every charge. The Premium can use its own battery to recharge the pair.
QuelleVerwandtes Zubehör
Aktuelle Angebote werden geprüft…
Dokumentation geprüft am 18. Nov. 2026