Open Fortell case with red and blue hearing-aid wells, case button and side USB-C port

Fortell Charging Case

Charge and store compatible Fortell AI Hearing Aids at home and away from a wall outlet.

What Fortell Charging Case does

Keep your Fortell AI hearing aids charged at home or on the go. The case has a charging spot for each ear and its own rechargeable battery. A full case can recharge a pair up to three times away from an outlet. Separate lights show the charge of each hearing aid and the case.

Which hearing aids work with Fortell Charging Case?

Charging

  • Fortell AI Hearing Aids

    Supplied USB-C cable and wall power adapter: Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit.

    Unplugged operation from the built-in case battery: Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit. Keep case battery charged.

Choose the exact model printed on your hearing aids or paperwork. A family match does not establish support for every model in that family.

What do you want to do?
View documented devices and setups
  • Fortell AI Hearing Aids · Exact model

    Supplied USB-C cable and wall power adapter · charging

    Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit.

    Documented support

    Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit.

      Source · 2026-11-18
    • Fortell AI Hearing Aids · Exact model

      Unplugged operation from the built-in case battery · charging

      Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit. Keep case battery charged.

      Documented support

      Use the designated CCUB-001-DGR case and matched blue left/red right wells. Seating and charging lights confirm physical fit. Keep case battery charged.

        Source · 2026-11-18

      Documented features

      Power and charging

      Automatic hearing-aid power
      Powered case turns the hearing aids off when seated. Removing the aids turns them back on.

      If the case has no available power, inserted hearing aids stay on.

      Documentation · 2026-11-18
      Case battery is not user-replaceable

      No user replacement. Contact Fortell if battery service is needed.

      Documentation · 2026-11-18
      Charging-case recharge time
      8 hours

      Typical time to recharge the case from external power, with or without aids inside. Temperature can affect time.

      Documentation · 2026-11-18
      Charge case and aids together
      Supported

      Both recharge while the case is attached to wall power.

      Setup: Supplied USB-C cable and wall power adapter

      Documentation · 2026-11-18
      Unpowered storage behavior
      For storing the case for more than 14 days, start with a full case and top it up at least every three weeks.

      No measured idle discharge rate. If storing the hearing aids with the case, Fortell directs you to leave the case connected.

      Documentation · 2026-11-18
      Hearing-aid and receiver fit
      Fortell AI Hearing Aids in their designated left and right wells.

      No cross-brand or generic Qi hearing-aid fit. Check with Fortell for earmold seating or replacement fit.

      Documentation · 2026-11-18
      Charging indicators
      Pulsing white or orange for charging, three white aid lights for complete, solid red for moisture and three flashing red for incorrect seating. The side lights show the separate case reserve.

      No lights can mean a drained device. Open the lid and verify case power.

      Documentation · 2026-11-18
      Charging method
      Seat each aid in its matching dedicated well. The case can draw power from its USB-C supply or its stored battery.

      Confirm each aid sits correctly by checking its lights.

      Documentation · 2026-11-18
      Charging slots
      2 aids

      One blue-marked left well and one red-marked right well.

      Documentation · 2026-11-18
      Charging temperature limits
      41–104°F (5–40°C) in current revision H, with 15% to 90% noncondensing humidity.

      Use the current narrower range. Original FCC-submitted revision A had a wider temperature specification.

      Documentation · 2026-11-18
      Full hearing-aid charge time
      2.5 hours

      Current rev G and H IFUs give 150 minutes from empty, supported by the newer article. Earlier IFU/support figures were three hours. Treat as current guidance, not a universally verified hardware speed.

      Documentation · 2026-11-18
      Electrical input requirements
      Use Fortell’s supplied USB-C cable and wall power adapter.

      The written IFU did not establish a wattage or amp rating for this case. Use an original adapter.

      Setup: Supplied USB-C cable and wall power adapter

      Documentation · 2026-11-18
      Lid behavior while charging
      Charging can continue with the lid closed. Fortell says closing it can reduce hearing-aid charge time.

      With the lid open, separate lights show case and hearing-aid status. Unplugged case lights turn off shortly after closing.

      Documentation · 2026-11-18
      Portable charger battery
      Built-in lithium-ion rechargeable case battery.

      Fortell publishes the number of full pair charges, but no mAh or Wh capacity.

      Documentation · 2026-11-18
      Charges away from a power outlet
      SupportedDocumentation · 2026-11-18
      Portable full pair charges
      Up to 3 full charges

      Capacity can decline as the battery ages.

      Documentation · 2026-11-18
      Power adapter included
      Supported · With conditions

      Supplied with the original hearing-aid kit. The exact replacement case box contents have not been established.

      Setup: Supplied USB-C cable and wall power adapter

      Documentation · 2026-11-18
      Power bank use
      The case has an internal power bank for its matched hearing aids.

      Charging the case itself is documented only with the supplied USB-C cable and wall adapter. External power banks are not verified.

      Setup: Unplugged operation from the built-in case battery

      Documentation · 2026-11-18
      Power connector
      USB-C input on the side of the case.

      Fortell directs owners to use its original approved power adapter and cable.

      Setup: Supplied USB-C cable and wall power adapter

      Documentation · 2026-11-18
      Quick charge duration
      15 minutes

      Current typical-from-empty estimate. Actual charge time and use vary.

      Documentation · 2026-11-18
      Runtime after quick charge
      3.2 hours

      Typical use after 15 minutes in current revisions. Original rev A states 2.4 hours; mode, output and battery age affect use.

      Documentation · 2026-11-18
      USB-C power input
      SupportedDocumentation · 2026-11-18

      Care and fit

      Battery preparation for care
      Connect the case to its original adapter before initial use or fill its internal battery. Seat clean, dry aids in the matching wells.

      No user-replaceable cell preparation.

      Documentation · 2026-11-18
      Cleaning materials
      Use the supplied soft dry cloth to wipe moisture. Keep wells and connector free of dirt and chemicals.

      If the case becomes wet or stops working contact Fortell.

      Documentation · 2026-11-18
      No drying function

      Wipe aids dry before seating them. Moisture alarms request manual drying and the complete mode/controls documentation has no drying cycle.

      Documentation · 2026-11-18
      No UV cleaning cycle

      The mode and control reference describes charging, pairing and resets only. It has no UV function.

      Documentation · 2026-11-18

      Design and everyday use

      Control accessibility
      Left blue and right red wells, separate levels for both aids and the case, and differing flash patterns for moisture versus seating.

      A user can check the case lights without opening an app. Use the visual diagram for control placement.

      Documentation · 2026-11-18
      Included items
      Charging case, USB-C cord and wall power adapter in the Fortell AI Hearing Aids package

      Fortell does not say whether a replacement case order includes a cable or adapter.

      Documentation · 2026-11-18
      Routine maintenance
      Wipe moisture off before charging and keep the wells and case clean and dry. Disconnect the cable when carrying the case.

      Keep the case plugged in if storing aids in it long term. For standalone storage recharge the case at least every three weeks.

      Documentation · 2026-11-18
      Operating conditions
      32–113°F (0–45°C) and 15% to 90% noncondensing humidity.

      Actual charging temperatures are narrower in the current IFU.

      Documentation · 2026-11-18
      Physical controls
      Hinged lid, Two color-marked charging wells, Central case button, USB-C port, Aid and case status lights

      Press once for hearing-aid pairing, hold five seconds to restart the aids, or hold for 15 seconds to reset the case.

      Documentation · 2026-11-18
      Regional variants
      Dark gray CCUB-001-DGR, US registration DI 00860014635823.

      No additional public charger model variant or cross-region fit was verified. The exact commercial dates of different written ratings are not established.

      Documentation · 2026-11-18
      Replacement parts
      Replacement charging case sold directly by Fortell

      Ask Fortell about an approved cable or adapter. No separate part prices or box contents verified.

      Documentation · 2026-11-18
      Required extras
      Matching Fortell AI Hearing Aids, Original Fortell USB-C cable and adapter to refill the case

      The case battery powers charging away from an outlet. No app is required for charging.

      Documentation · 2026-11-18
      Repair and service options
      Contact Fortell to purchase a replacement charger, report charging faults, or discuss battery service.

      Do not open the case or attempt to replace its battery.

      Documentation · 2026-11-18
      Status indicators
      Separate left and right hearing-aid light groups, Separate case charge lights beside the USB-C connector, Pulsing orange or white for charging, Steady white for full hearing-aid charge, Solid red for moisture or flashing red for incorrect seating, Blue for pairing

      See the figure and status table for percentages and the controls guide for pairing.

      Documentation · 2026-11-18
      Storage conditions
      Store dry between 14°F and 113°F (−10 to 45°C), up to 90% noncondensing humidity.

      The guide gives different transport conditions and instructs owners to disconnect the USB-C cable for transport.

      Documentation · 2026-11-18
      Warranty terms
      The three-year hearing-aid warranty and loss coverage are not a three-year case warranty. Fortell excludes accessories from the relevant aid terms.

      Request confirmed case-specific terms when ordering a replacement.

      Documentation · 2026-11-18

      How to set up Fortell Charging Case

      Plug the supplied USB-C cable and power adapter into a wall outlet to charge the case. Place the left hearing aid in the blue slot and the right hearing aid in the red slot. Pulsing white or orange lights show charging. Close the lid while they charge. If three red lights flash, remove the affected aid and reseat it.

      What to check before buying

      Use the designated case and the supplied USB-C cable and power adapter. The hearing aids stay on if the case is out of power and unplugged. Solid red lights tell you to dry the aid before charging it. Fortell sells replacement chargers directly. Confirm your exact case if ordering a replacement.

      Holds up to three extra charges for a Fortell pair

      If you’re comparing hearing-aid systems for travel, a full Fortell case can recharge its pair up to three times, compared with up to two charges for a Delight pair in the ELEHEAR Delight Charger. Those figures describe what each system can do with its own case.

      Source

      Allow about eight hours to recharge the case itself

      Before a trip, allow about eight hours to recharge the Fortell case itself. For comparison across hearing-aid systems, the ELEHEAR Beyond 2 Pro Charging Case takes up to 2½ hours to recharge. Each case powers its own pair of hearing aids.

      Source

      Match each hearing aid to its charging well

      Plug the supplied USB-C cable and power adapter into a wall outlet to charge the case. Place the left hearing aid in the blue slot and the right hearing aid in the red slot. Pulsing white or orange lights show charging. Close the lid while they charge. If three red lights flash, remove the affected aid and reseat it.

      Source

      Check the lights before closing the case

      If three lights turn solid red, remove the aid and wipe away moisture. If they flash red, reseat the aid. Check the case lights beside the USB-C port if neither hearing aid shows that it’s charging.

      Source

      An empty case leaves the hearing aids on

      Plug the case into its original wall adapter or charge its battery before putting your hearing aids away. The hearing aids keep using their own charge when the case runs out of power.

      Source