- Accessory directory
- Hearing Aid Chargers
- Phonak Charger Case Go
Phonak Charger Case Go
A charging case for compatible Audéo Life hearing aids, with its own battery for charging away from an outlet. Phonak says a charged case provides up to three full charges for a pair.
What Charger Case Go does
Charger Case Go has an internal battery. Phonak documents it for Audéo L-RL and P-RL; the local model match here is Audéo Lumity Life (L-RL).
Which hearing aids work with Phonak Charger Case Go?
Charging
Choose the exact model printed on your hearing aids or paperwork. A family match does not establish support for every model in that family.
View documented devices and setups
- Phonak Audéo Lumity Life · Exact model
Hearing aids seated in the matching charger · charging
Documented supportSource · 2026-11-17
Documented features
Power and charging
- Automatic hearing-aid power
- The hearing aids turn off when inserted. Automatic power-on after removal depends on their settings.
Applies to the Audéo hearing aids covered by the US guide.
Documentation · 2026-11-19 - Case battery is not user-replaceable
Phonak describes the internal lithium-polymer battery as non-removable.
Documentation · 2026-11-19- Charge case and aids together (not supported)
The case battery pauses charging while the hearing aids charge.
Documentation · 2026-11-19- Unpowered storage behavior
- Unplugging the case allows it to continue charging the aids until the case battery is empty.
Store the aids separately for an extended period without use.
Documentation · 2026-11-19 - Hearing-aid and receiver fit
- Audéo L-RL (Lumity Life) and P-RL (Paradise Life)
Check the suffix on the hearing aid against the Phonak charger chart.
Documentation · 2026-11-17 - Charging indicators
- The hearing-aid indicator shows charging progress and stays green at full charge.
The green light on the case also confirms external power.
Documentation · 2026-11-19 - Charging slots
- 2 aids
Use the slot with the corresponding left or right marking.
Documentation · 2026-11-19 - Charging temperature limits
- 41–86°F (5–30°C)
Temperature range for charging the named Audéo hearing aids.
Documentation · 2026-11-19 - Full hearing-aid charge time
- 3 hours
Up to three hours for the listed Audéo hearing aids from empty.
Documentation · 2026-11-19 - Electrical input requirements
- 5 V DC, 1 A charger input
The compatible external power supply delivers 5 V DC, 1 A.
Documentation · 2026-11-19 - Lid behavior while charging
- The lid can be closed during charging.
Place the hearing aids in their matching wells and the earpieces in the cavity.
Documentation · 2026-11-19 - Charges away from a power outlet
- Supported
The charged internal battery can power the charger away from an outlet.
Documentation · 2026-11-19 - Portable full pair charges
- 3 pair charges
Up to three charges of the hearing aids from a fully charged case.
Documentation · 2026-11-19 - Power adapter not included
The US guide specifies that the power plug is supplied separately.
Documentation · 2026-11-19- Power connector
- USB-C
The supplied cable runs from USB-A on the power supply to USB-C on the charger.
Documentation · 2026-11-19 - USB-C power input
- SupportedDocumentation · 2026-11-17
Design and everyday use
- Included items
- USB charging cable
The US guide lists a USB cable shorter than 3 m.
Documentation · 2026-11-19 - Routine maintenance
- Keep the inserts clean and use a lint-free cloth. Disconnect the charger from the power supply for cleaning.
Allow the hearing aids and charger to dry before charging.
Documentation · 2026-11-19 - Physical controls
- Reset button
The US guide describes a reset procedure with the case connected to power.
Documentation · 2026-11-19 - Required extras
- Compatible USB wall power adapter
Use a supply matching the voltage and current specified in the US guide.
Documentation · 2026-11-19 - Status indicators
- Power connection light, Hearing-aid charging lights, Internal case battery lights
The charging LEDs on the aids are separate from the lights on the case.
Documentation · 2026-11-19 - Warranty terms
- One-year limited international warranty on manufacturing and material defects. Local terms may differ.
Proof of purchase is required. Ask the supplying hearing care professional about local coverage.
Documentation · 2026-11-19
How to set up Phonak Charger Case Go
Connect the USB cable to a compatible 5 V wall power adapter. The US package lists the cable and requires a separate power plug. Place the aids in the blue left and red right slots with the earpieces in the cavity. Their lights turn solid green at full charge.
What to check before buying
The claim of three charges applies to a pair of hearing aids and comes from Phonak documentation. Ease, Ease Go and later Infinio chargers are different products. The US guide specifies a separate wall power adapter.
Choosing the matching charging case
For Lumity, check the model suffix before choosing a case. Charger Ease fits the rechargeable L-R and L-RT. Life models with the L-RL suffix use the Life Charger or Charger Case Go. The charged Go case can top up the aids away from an outlet.
SourceOther devices named in the documentation
These names have not been matched to an exact device in our catalog. They do not create verified matches in the finder.
Checking current offers…
Documentation checked Nov 19, 2026