Oticon Charger miniRITE

Recharge compatible Oticon miniRITE hearing aids in the open desktop cradle.

What Oticon Charger miniRITE does

The desktop charger recharges two compatible Oticon miniRITE hearing aids through contacts. Connect it to USB power and place each aid in its color-coded slot. Oticon lists up to two hours from empty to full at normal room temperatures.

Which hearing aids work with Oticon Charger miniRITE?

Charging

  • Oticon Reveal miniRITE R

    Use the desktop case marked for compatible contact-charging miniRITE styles. Keep it connected to power while the aids are seated. Verify the desktop charger label for the matching contact-charging miniRITE hearing aid.

  • Oticon Intent miniRITE R

    Use the matching contact-charging miniRITE case. Oticon CROS RE documentation confirms the common chassis across Reveal, Intent and Play SI, but the charging-well label should be verified. Verify the desktop charger label for the matching contact-charging miniRITE hearing aid.

Choose the exact model printed on your hearing aids or paperwork. A family match does not establish support for every model in that family.

What do you want to do?
View documented devices and setups
  • Oticon Reveal miniRITE R · Exact model

    Compatible miniRITE aids in the externally powered contact desktop charger · charging

    Use the desktop case marked for compatible contact-charging miniRITE styles. Keep it connected to power while the aids are seated.

    Requires additional setup

    Use the desktop case marked for compatible contact-charging miniRITE styles. Keep it connected to power while the aids are seated.

    • Verify the desktop charger label for the matching contact-charging miniRITE hearing aid.
    Source · 2026-11-18
  • Oticon Intent miniRITE R · Exact model

    Compatible miniRITE aids in the externally powered contact desktop charger · charging

    Use the matching contact-charging miniRITE case. Oticon CROS RE documentation confirms the common chassis across Reveal, Intent and Play SI, but the charging-well label should be verified.

    Requires additional setup

    Use the matching contact-charging miniRITE case. Oticon CROS RE documentation confirms the common chassis across Reveal, Intent and Play SI, but the charging-well label should be verified.

    • Verify the desktop charger label for the matching contact-charging miniRITE hearing aid.
    Source · 2026-11-18

Documented features

Power and charging

Unpowered storage behavior
Keep the charger powered whenever the hearing aids are seated. Charging stops automatically when full.

The guide does not quantify the hearing-aid drain rate when the charger is unplugged.

Documentation · 2026-11-18
Hearing-aid and receiver fit
Use the miniRITE contact version for Oticon Reveal miniRITE R. Oticon identifies its rechargeable CROS RE as sharing chargers with the miniRITE designs of Reveal, Intent and Play SI. Match the hearing aid and charger label before ordering. · With conditions

Use the separately marked miniBTE R version when appropriate. The manufacturer describes support for different speaker lengths and earpieces without listing individual fit limits.

Setup: Compatible miniRITE aids in the externally powered contact desktop charger

Documentation · 2026-11-18
Charging indicators
Green charger light confirms power. Aids pulse orange at low charge, show steady orange at four or more hours of expected use, and green when full.Documentation · 2026-11-18
Charging method
Magnetic seating holds the hearing-aid contacts against the matching well.

The current Reveal generation uses contact charging. The earlier Oticon 263329US model is inductive.

Documentation · 2026-11-18
Charging slots
2 aids

One left and one right charging well.

Documentation · 2026-11-18
Charging temperature limits
Charging is disabled below 41 °F and above 104 °F. Best charging is at 59–95 °F.

Oticon specifies up to six hours at 41–59 °F and 95–104 °F, and up to two hours at 59–95 °F.

Documentation · 2026-11-18
Full hearing-aid charge time
2 hours · With conditions

From empty under normal conditions at 59–95 °F. May take up to six hours near the operating temperature boundaries.

Setup: Compatible miniRITE aids in the externally powered contact desktop charger

Documentation · 2026-11-18
Electrical input requirements
Charger input 5 V DC. Supplied wall adapter outputs 5 V DC at 1 A.

Oticon reports under 0.1 A charger draw with two hearing aids and under 5 mA with no aids inserted. The separate external-source minimum is 500 mA.

Documentation · 2026-11-18
Lid behavior while charging
The desktop charger has an open top with no hinged lid.

The manufacturer labels its separate lidded enclosure SmartCharger.

Documentation · 2026-11-18
Charging requires external power

Requires a connected USB power source. An external power bank can power the case if it meets Oticon’s requirements.

Setup: Compatible miniRITE aids in the externally powered contact desktop charger

Documentation · 2026-11-18
Power adapter included
Supported

The power adapter is listed in the U.S. manufacturer’s package.

Documentation · 2026-11-18
Power bank use
Use a USB 2.0-compliant external bank providing at least 500 mA without automatic shutdown. · With conditions

Keep it connected throughout charging.

Setup: Desktop charger with a compatible external USB supply

Documentation · 2026-11-18
Power connector
Detachable 1.5 m USB-A to USB-C cable.Documentation · 2026-11-18
Quick charge duration
15 minutes

Setup: Compatible miniRITE aids in the externally powered contact desktop charger

Documentation · 2026-11-18
Runtime after quick charge
4 hours · With conditions

With 15 minutes of charging. Expected wear time varies with streaming, environment, hearing loss, feature use and battery age.

Setup: Compatible miniRITE aids in the externally powered contact desktop charger

Documentation · 2026-11-18
USB-C power input
Supported

The charger inlet uses a detachable USB-C cable with a USB-A plug on the source end.

Documentation · 2026-11-18

Care and fit

Cleaning materials
Use a dry cloth. Keep water, cleaning fluids and cotton swabs out of the charging and USB-C ports.Documentation · 2026-11-18

Design and everyday use

Control accessibility
Color-coded wells mark left and right. Magnets help seat compatible aids.

The sources describe a visual indicator. Audible or tactile confirmation was not verified.

Documentation · 2026-11-18
Dimensions
70.4 × 57.5 × 44.5 mm

Width × height × depth. Shared manufacturer specifications for the miniRITE/miniBTE desktop designs.

Documentation · 2026-11-18
Included items
Desktop charger, USB-A to USB-C cable, Wall power adapter

The types of power plug vary by country.

Documentation · 2026-11-18
Routine maintenance
Keep the charger dry and dust the ports with a dry cloth. Disconnect the cable for transport.Documentation · 2026-11-18
Operating conditions
41–104 °F, 5–93% noncondensing humidity and 700–1060 hPa.

The manual recommends a dry, 59–95 °F environment for regular use.

Documentation · 2026-11-18
Physical controls
No power switch in the desktop diagram, Red right and blue left charging wells, Detachable rear USB-C power inlet

The desktop charger starts when connected to power.

Documentation · 2026-11-18
Regional variants
Power plug varies by country.

U.S. documentation; other regional package components were not verified.

Documentation · 2026-11-18
Required extras
Compatible rechargeable miniRITE hearing aid, Powered outlet or permitted external USB supply

Use the supplied 5 V/1 A adapter for a wall outlet.

Documentation · 2026-11-18
Repair and service options
Ask a hearing care professional for service if correct power, temperature and seating do not fix a charging fault.Documentation · 2026-11-18
Status indicators
Green charger light when plugged in, Hearing-aid lights show charging progress and full chargeDocumentation · 2026-11-18
Storage conditions
−13–158 °F, 5–93% noncondensing humidity and 700–1060 hPa during transport and storage.

Unplug the USB cable when transporting the charger.

Documentation · 2026-11-18
Warranty terms
International manufacturer warranty covers manufacturing and material defects. Misuse, unauthorized repairs and some accessories are excluded.

The certificate leaves the duration blank. Confirm the U.S. period with the seller or hearing care professional.

Documentation · 2026-11-18

How to set up Oticon Charger miniRITE

Use the supplied USB cable and wall power adapter. The charger light turns green when it has power. Seat the right hearing aid at the red mark and the left at the blue mark. If the aids are charging, their lights pulse orange with a low battery, show steady orange with at least four hours of estimated use, and turn green when full. Keep the charger powered while the hearing aids are seated.

What to check before buying

This open desktop charger requires external power. The lidded SmartCharger has a built-in battery. Earlier inductive chargers and the miniBTE well are separate models. Confirm the marking on the case before buying.

Check the charger and hearing-aid lights

Use the supplied USB cable and wall power adapter. The charger light turns green when it has power. Seat the right hearing aid at the red mark and the left at the blue mark. If the aids are charging, their lights pulse orange with a low battery, show steady orange with at least four hours of estimated use, and turn green when full. Keep the charger powered while the hearing aids are seated.

Source

Needs external power while charging

The desk charger needs a powered USB connection throughout charging. If you need to recharge without a cable, the matching SmartCharger has a built-in battery and a protective lid. Choose the exact miniRITE version for your hearing aid.

Source

Other devices named in the documentation

These names have not been matched to an exact device in our catalog. They do not create verified matches in the finder.

Checking current offers…

Documentation checked Nov 18, 2026